ASCB1-63-C16 1P Smart Circuit Breaker

ASCB1-63-C16 Over Current / Power / Temp. Protection; Over / Under Voltage Protection; Short Circuit Protection; Leakage Current Protection. Appearance PatameterModelASCB1-63ASCB1LE-63Pole1P/2P/3P/4P2P/4PGrade of Shell63ARated Voltage230V(1P/2P)、400V(3P/4P)Rated Current6A,10A,16A,20A,25A,32A,40A,50A,63AInstantaneous Unbuckle TypeC/DRated Short-circuit Breaking Capacity6000AProtectOver-current ProtectionDefault 100% rated current alert,110% Rated current trip with adjustable thresholdShort-circuit Protection5-10 Rated current for 0.04 seconds for circuit break protectionOverload ProtectionDefault 100% rated power […]

  • Fast And Safe Logistics
  • Sample Available

ASCB1-63-C16

    • Over Current / Power / Temp. Protection;
    • Over / Under Voltage Protection;
    • Short Circuit Protection;
    • Leakage Current Protection.

Appearance



Patameter




Model
ASCB1-63
ASCB1LE-63
Pole
1P/2P/3P/4P
2P/4P
Grade of Shell
63A
Rated Voltage
230V(1P/2P)、400V(3P/4P)
Rated Current
6A,10A,16A,20A,25A,32A,40A,50A,63A
Instantaneous Unbuckle Type
C/D
Rated Short-circuit Breaking Capacity
6000A








Protect
Over-current Protection
Default 100% rated current alert,
110% Rated current trip with adjustable threshold
Short-circuit Protection
5-10 Rated current for 0.04 seconds for circuit break protection
Overload Protection
Default 100% rated power alert,110% Rated power trip with adjustable threshold
Over-voltage Protection
Default 110% rated voltage alert,120% rated voltage trip with adjustable threshold
Under-voltage Protection
Default 90% rated voltage alert,80% rated voltage trip with adjustable threshold
Over-temperature Protection
Default 80℃ alert,100℃ trip, the threshold is adjustable
Leakage Protection
No
Default 20mA alert, 30mA trip, the threshold is adjustable
Leakage self-Inspection
No
Manual button self-inspection
Mechanical Life
20000 times
Electrical Life
6000 times
Levels of Protection
IP20
Connection Capacity
1-35mm²
Elevation Requirements
2000m
Ambient Temperature
-10℃~55℃,the average temperature at 24h was no higher than 40℃
Environmental Requirements
No explosion hazard, no conductive dust, no sufficient corrosion of metal and damaged insulation, no significant vibration
Relative Humidity
At + 40℃, the relative humidity of the air is 50% and can have high relative humidity at lower temperatures
Storage Temperature
-20℃-70℃
Class of Pollution
Installation Type
Way to Installation
Standard 35mm guide rail installation








Function




ASCB1 Series Intelligent MCB Function


ASCB1-63
· Can monitor voltage, current, power, power and temperature in real time
· with overpressure, underpressure, overload, short circuit, overcurrent, and overtemperature and other protection functions
· With local manual lever, local electric control, local lock, remote control, timing control and other control function
· Guide rail type installation, optional pole number 1P / 2P / 3P / 4P
· Standard RS-485 (MODBUS) communication; optional buckle curve type C / D





Wiring

Typical Connection

FAQ



Q: Can the circuit breaker data be collected through RS485 communication?


A: The circuit breaker has its own RS485 communication interface, and it does not need to be equipped with an ASCB1-M gateway to access the customer system, but the customer needs to provide the circuit breaker with DC12V 12A auxiliary power supply




Q: How many circuit breakers can a gateway carry?


A: 16PCS


Q: How Gateways and Circuit Breakers are Networked?


A: The gateway and the circuit breaker are connected by a 4pin cable, a set of DC12V auxiliary power supply, and a set of RS485 communication lines.
The connection between the circuit breaker and the circuit breaker is the same.
One-key addressing operation through the gateway


Q: Does the circuit breaker need to be equipped with additional accessories?


A: 1. Internally integrate various sensor modules, including: current sensor, leakage transformer, temperature sensor, etc.;
2. The circuit breaker integrates the release function, which can realize remote opening and closing operations;
3. Configure the circuit breaker network cable