DTSD1352-4S Multi-circuit Energy Meter for Tower Base Stations

● Rated Current: AC250A, 100A
● Rated Voltage: 3x220V/380V AC (3P4W)
● Measure up to 4 circuit 3 phase
● Measure all electric parameters
● RS485 interface Modbus-RTU communication
● LCD Display; 35mm DIN Rail Installation
● Work with RJ45 port External Split core CTs

  • Fast And Safe Logistics
  • Sample Available




General


DTSD1352-4S series DIN-rail type multi-circuit power meter is mainly used for the full electric parameter measurement of multiple circuits, and can be connected to the current input of 4 three-phase circuits or 12 single-phase circuits at the same time. It can measure parameters such as voltage and current, power, power factor, phase angle, unbalance, and harmonics.

Front Panel

Function

Accuracy

Active power: Class 1
Reactive power: Class 2

Frequency

Range: 45 - 65Hz

Pulse output

Output method:optocoupler pulse with open collector

Power Consumption

≤10VA

Dimension (L*W*H)

Panel size (L×W×H): 87.8*72*71.5 mm

Installation

Din 35mm

Current
Overload: 1.2 times rated value (continuous)

Parameters

Auxiliary power AC/DC 85~265V; Consumption≤10VA;
Input Frequency 45~65Hz;
Voltage AC 3×220V/380V; Overload: 1.2 times of rated value (continuous); 2 times of rated value / 1s; Power consumption: ≤ 0.5VA;each channel)
Current Rated value: Secondary input rated current:50mA;Overload: 1.2 times rated value (continuous); 10 times rated value/1 second;power consumption: ≤ 0.5VA(each channel);
Measurement accuracy Frequency: 0.05Hz, voltage and current: 0.5 class, active energy: 1 class, reactive energy: 2 class; 2nd to 31st harmonic accuracy: ±1%;
Features Pulse output Output method: optocoupler pulse with open collector,the pulse constant defaults to 400imp/kWh (and active open input can only be either-or.);
Communication RS485 interface, Modbus-RTU protocol; baud rate 1200~38400;
Switching Input 2-way or 4-way passive dry contact input, built-in power supply; 2-way active wet node input (AC220V), identify the oil generator and mainsaccess (and pulse output can only be either-or.);
Switching Output Output method: relay normally open contact output; Contact rating: AC 250V/3A DC 30V/3A;

Dimension



Meter (L×W×H): 87.8*72*71.5mm

35mm Din rail installation; Tolerance: ±1mm



TypeRatioLine LengthAccuracyInstallation Method
AKH-0.66/W-9NY 50A/20mA50A/20mA(1+0.2)mClass 0.2Closed type, crystal head interface
AKH-0.66/K-Φ10N 50A/20mA50A/20mA(1+0.2)mClass 0.5Open type, crystal head interface
AKH-0.66/W-12NY 100A/50mA100A/50mA(1+0.2)mClass 0.2Closed type, crystal head interface
AKH-0.66/K-Φ16N 100A/50mA100A/50mA(1+0.2)mClass 0.5Open type, crystal head interface
AKH-0.66/W-20Y 200A/50mA200A/50mA(1+0.5)mClass 0.2Closed type, crystal head interface
AKH-0.66/K-Φ24N 200A/50mA200A/50mA(1+0.5)mClass 0.5Open type, crystal head interface
AKH-0.66/W-30NY 250A/50mA250A/50mA(1+0.5)mClass 0.2Closed type, crystal head interface
AKH-0.66/K-Φ24N 250A/50mA250A/50mA(1+0.5)mClass 0.5Open type, crystal head interface
AKH-0.66-TD-Φ60-NY300-1000A/50mA(1+0.5)mClass 0.2Closed type, crystal head interface
AKH-0.66/K-Φ36N 400A/50mA400A/50mA(1+0.5)mClass 0.5Open type, crystal head interface
AKH-0.66/K-Φ36N 600A/50mA600A/50mA(1+0.5)mClass 0.5Open type, crystal head interface







Installation








Wiring










Network









Package


MINIMUM PACKAGE





MINIMUM PACKAGE

Package Dimension(1 PC)

170*150*130mm

Package Weight(1 PC)

0.245Kg

WHOLE BOX PACKAGE

Package Dimension(36 PCS)

540*530*480mm

Package Weight(36 PCS)

10.5kG

PRODUCT HS CODE

9028301400

ATTENTION !

The above packing and weight data are only refer to model ADW210.

For other models or optional functions, please contact the salesman for details, thank you for your cooperation!











How can I help you?