AMC72L-AI Single Phase AC Current Meter

AMC series meters adopt AC sampling technology, which can measure the current ,voltage,power, power factor and electric energy parameters in the power grid separately. It can set the magnification through the panel membrane switch. The meters have RS485 communication interface, adopt Modbus protocol; also can convert the power signal into a standard DC analog signal.

  • Fast And Safe Logistics
  • Sample Available

AMC72L-AI

    • Single phase ammeter
    • Paulus cruore
    • Single phase ammeter
    • RS485 And Modbus-RTU protocol
    • Input AC 1A Or 5A

Parameters

Communication
RS485(Modbus-RTU)

Display
LCD display, set multiplying power

Rated I
AC current: AC1A, 5A

Accuracy
Active energy: Class 0.5

Installation
Panel mounted

Dimension(L*W*H)
Panel size (L×W): 75*75mm
Cutout(L×W): 67*67mm
Depth (H): 94.3mm

Consumption
Current: Power consumption< 0.5VA;
Auxiliary power supply: power consumption≤5VA

Auxiliary power supply
AC 220V



Technical Datasheet




Technical Parameter

Value






Input

Rated Value

AC voltage:Single phaseAC 100V,400V

Three phaseAC 100V,400V,660V(UL-L,Only 72/ 96)

AC current:AC1A,5A;

Overload

Voltage: 1.2 times rated value(continuous); 2 times rated value /1 second

Current:1.2 times rated value(continuous); 10 times rated value /1 second

Frequency

45Hz~65Hz

Power Consumption

Power consumption of each voltage,current input circuit is less than 0.5VA

Accuracy

Class 0.5






Function

Display

LED or LCD

Communication

RS485,Modbus-RTU protocol;(1 start bit,8 data bit,1 stop bit,no parity)

Baud Rate 2400/4800/9600/19200 bps etc.

Alarm

1 channel passive relay,contact capacity 3A/30VDC,3A/250VAC, Used for high,low,unbalance alarm etc.

Analog

DC4~20mA,( load <500Ω)

(note:Shielded wire is specially selected for the above signal input and output)

Switching

Input:4 channel or 2 channel dry contact Input,built in power supply

Output:2 channel switching output,NO relay contact,capacity:3A/30VDC,3A/250VAC

Auxiliary Supply

AC/DC 85-265V

Power Consumption

<5VA

Insulation resistance

≥ 100MΩ

Power frequency withstand voltage

Between power supply set of terminals and signal input,output set of terminals 2kV/1min (RMS)

Between the shell and all set of terminals(except the set of terminals reference voltage less than 40V) AC 4kV


Environment

Temperature

Operation: -10℃~+55℃Storage: -25°C ~+70°C

Humidity

≤95%RH,no condensation,without corrosive gas

Altitude

≤ 2500m






Dimension

Wiring

Network

Installation



Package




MINIMUM PACKAGE







MINIMUM PAKAGE


Package dimensions(1 PC)

170*150*130mm

Pakage Weight(1 PC)

0.62Kg


WHOLE BOX PAKAGE


Package dimensions(16 PCS)

450*245*200mm

Pakage Weight(16 PCS)

3.66kG


PRODUCT HS CODE


9028301400


ATTENTION !

The above packing and weight data are only refer to model AMC72L-AI.

For other models or optional functions, please contact the salesman for details, thank you for your cooperation!