BM800 Series Signal Conditioner


● 6.2mm Ultra-thin Design: Saves over 50% cabinet space
● DIP Switch Configuration: Tool-free, flexible signal range selection
● Galvanic Isolation: 1.5kV AC isolation among input, output, and power
● High Accuracy: Up to 0.1% F.S. conversion
● Wide Temperature Range: -20°C to +60°C operation
● Low Power Consumption: ≤2W typical
● IP20 Protection: Suitable for control cabinet installation
● CE & IEC Compliance: Meets IEC61000-6-2 and IEC61000-6-4 EMC standards

  • Fast And Safe Logistics
  • Sample Available


General


The BM800 Series Signal Conditioner is a next-generation signal conditioning device engineered for industrial automation and control systems. With an ultra-thin 6.2mm profile, it saves over 50% of installation space compared to conventional products, making it an ideal solution for high-density cabinet installations.

Designed for DIN 35mm rail mounting, this series provides galvanic isolation between input, output, and power supply circuits (≥1500V AC), ensuring reliable signal transmission in electrically noisy industrial environments. The entire series features 1-channel input and 1-channel output architecture, with flexible configuration via DIP switches on most models.



Product Models


Model

Input Signal

Output Signal

DIP Switch

BM800-VI/VI-11DC 0/4~20mA, 0/1~5V, 0/2~10VDC 0/4~20mA, 0/1~5V, 0/2~10VConfigurable
BM800-RPSI/I-110/4~20mA (2/3/4-wire transmitters)DC 0/4~20mAFixed
BM800-TC/VI-11Thermocouple Type K, Type JDC 0/4~20mA, 0/1~5V, 0/2~10VConfigurable
BM800-TR/VI-11Pt100 (2/3/4-wire)DC 0/4~20mAConfigurable




Technical Specifications

General Specifications
Parameter Specification
Dimensions 6.2mm × 97mm × 100mm
Weight Approx. 70g
Mounting DIN 35mm standard rail
Supply Voltage 24V DC (Operating range: 20–35V DC)
Power Consumption ≤2W
Operating Temperature -20°C to +60°C
Storage Temperature -40°C to +80°C
Relative Humidity ≤95% RH, non-condensing
Max Operating Altitude ≤2000m
Dielectric Strength ≥1500V AC, 50Hz, 60s (I/O/Power)
Insulation Resistance ≥100MΩ
Pollution Degree 2
Overvoltage Category II
Ingress Protection IP20
EMC Compliance IEC61000-6-2, IEC61000-6-4
Analog Input Models (BM800-VI/VI-11)
Parameter Specification
Input Channel 1
Input Signal (Configurable) DC 0/4~20mA, 0/1~5V, 0/2~10V
Max Input Current DC 100mA
Max Input Voltage DC 13V
Input Impedance Current: 50Ω; 0/1-5V: 1MΩ; 0/2-10V: 2MΩ
Output Signal (Configurable) DC 0/4~20mA, 0/1~5V, 0/2~10V (Active Signals)
Max Output Current DC 40mA
Max Output Voltage DC 16V
Conversion Accuracy ≤0.1% F.S.
Temperature Drift 50ppm/°C
Response Time (10-90%) ≤5ms
Output Ripple ≤50mVpp (@250Ω)
Load Capacity Current Output ≤550Ω; Voltage Output ≥10kΩ
Thermocouple Input Model (BM800-TC/VI-11)
Parameter Specification
Input Channel 1
Input Signal Thermocouple Type K, Type J
Minimum Configurable Span 300°C
Output Signal (Configurable) DC 0/4~20mA, 0/1~5V, 0/2~10V
Max Output Current 25mA
Conversion Accuracy ≤0.1% F.S. (Input Range ≥1000°C)
Temperature Drift 100ppm/°C
Response Time (10-90%) ≤1s
Output Ripple ≤50mVpp (@250Ω)
Load Capacity Current Output ≤550Ω; Voltage Output ≥10kΩ
RTD Input Model (BM800-TR/VI-11)
Parameter Specification
Input Channel 1
Input Signal Pt100 (2/3/4-wire)
Minimum Configurable Span 50°C
Output Signal DC 0/4~20mA
Conversion Accuracy ≤0.1% F.S. (≥200°C full scale, 3/4-wire)
Temperature Drift 100ppm/°C
Response Time (10-90%) ≤1s
Load Capacity Current Output ≤550Ω

Applications


Industrial Automation: PLC and DCS system signal interfacing
Process Control: Signal conversion and isolation for sensors and transmitters
Power Monitoring: Current and voltage signal conditioning for energy management systems
Building Automation: HVAC and lighting control signal processing
Factory Automation: Machine control and monitoring signal isolation
Data Acquisition: Sensor signal conditioning for SCADA systems